Sensible capacity : 19.8
Model Number : DME22
Number of compressors : 1
MOQ : 1
Delivery Time : 5-8 weeks
Standard airflow (m³/h) : 6,000
Payment Terms : T/T
Air supply way : Upper /Lower
Price : USD 13351
Cooling capacity : 22KW
Supply Ability : 1000 sets /month
Product name : Precision air conditioner
Certification : ISO、CE
Electric heater (kW) : 6 ( optional )
Packaging Details : Cartons
Brand Name : Liebert
Number of fans : 1
Place of Origin : China
Maximum current (A) : 26.8
Product Introduction
The Liebert DataMate 3000-2 series provides continuous and stable environmental control for small and medium-sized computer rooms, server rooms, power rooms, communication equipment rooms, and precision control areas. The system is designed to remove the heat generated by IT and electronic equipment while supporting dependable temperature and humidity management.
The unit uses R410A refrigerant and a high sensible heat ratio, high-efficiency refrigeration system design. A Copeland scroll compressor is used in the refrigeration system. An optional energy-saving card can be selected for enhanced energy-saving performance. The manual also states that the series has obtained a China Energy-Saving Product Certification certificate.
The control system supports AI fault self-diagnosis and self-learning operation. The indoor unit display can show outdoor-unit operating status, helping operators monitor the system from the indoor interface. Group-control functions support backup and rotation operation. Remote monitoring and alarm functions are available to support remote operation and maintenance for edge sites.
The series uses qualified components and provides a wide input-voltage range together with multiple power protection functions. A power-failure recovery function enables automatic restart after power is restored, and the restart delay can be configured according to the application requirement.
The unit uses a compact structure and supports full front-side maintenance, which can help reduce service space requirements. The filter structure is compact, washable, reusable, and easy to maintain. The optional infrared humidification system is designed for easy maintenance and is less affected by water quality than conventional humidification methods.
The outdoor fan uses stepless full-speed control to support lower-energy and lower-noise operation. The standard condenser operating range is listed as -15°C to +45°C outdoor temperature. With an optional low-temperature component, the outdoor operating range can be extended to -34°C to -15°C, subject to the final configuration.
The series extends maximum cooling capacity from 5.5KW to 28.1 kW. Threaded quick connectors support efficient installation, while the long-piping connection technology provides greater installation flexibility. The DME22 and DME27 indoor units offer an upper-air or lower-air supply option; the other listed indoor-unit types use upper-air supply according to the manual table.
For server rooms and computer rooms that require stable cooling, controlled airflow, and continuous environmental management for IT equipment.
For technical spaces where high sensible cooling performance and reliable operation are important for maintaining equipment operating conditions.
For power-related rooms and equipment areas that generate continuous heat and require dedicated precision cooling rather than comfort air conditioning.
For indoor telecom facilities and communication equipment rooms that need dependable temperature and humidity control and remote alarm support.
For edge sites and outdoor technical enclosures where remote monitoring, alarm functions, low-temperature operation, and unattended operation can be important. Final environmental and installation requirements should be confirmed for each site.
For substations and electrical distribution facilities requiring dedicated cooling for control, protection, communication, or electronic equipment spaces.
For control rooms where stable environmental conditions support sensitive control systems and electronic instrumentation.
For inspection and testing environments that require more stable temperature and humidity conditions than standard comfort-cooling systems provide.
For storage areas containing electronic or technical equipment where controlled temperature and humidity can help maintain suitable storage conditions.
Pramaters
|
Type |
DME05 |
DME07 |
DME12 |
DME17 |
DME22 |
DME27 |
|
Cooling capacity at 24°C (kW) |
5.5 |
7.5 |
12.5 |
17 |
22 |
28.1 |
|
Sensible cooling capacity at 24°C, 50% RH (kW) |
5.0 |
7.0 |
11.3 |
15.5 |
19.8 |
25.3 |
|
Air supply |
Upper |
Upper |
Upper |
Upper |
Upper / Lower |
Upper / Lower |
|
Standard airflow (m³/h) |
2,000 |
2,000 |
3,100 |
4,300 |
6,000 |
7,300 |
|
Number of fans |
1 |
1 |
1 |
1 |
1 |
1 |
|
External static pressure (Pa) |
20–50 |
20–50 |
20–50 |
20–50 |
20–50 |
20–50 |
|
Number of compressors |
1 |
1 |
1 |
1 |
1 |
1 |
|
Electric heater (kW) |
3, optional |
3, optional |
3, optional |
5.5, optional |
6, optional |
6, optional |
|
Infrared humidifier (kg/h) |
1.5, optional |
1.5, optional |
1.5, optional |
3, optional |
3, optional |
3, optional |
|
Maximum current (A) |
20 |
20 |
20 |
25 |
26.8 |
30.3 |
|
Circuit breaker rating listed in manual (A) |
32 |
32 |
32 |
40 |
40 |
40 |
|
Cooling method options |
Water-cooled / Air-cooled |
Water-cooled / Air-cooled |
Water-cooled / Air-cooled |
Water-cooled / Air-cooled |
Water-cooled / Air-cooled |
Water-cooled / Air-cooled |
|
Dimension entry (W × D × H, mm) |
Net weight (kg) |
|
510 × 385 × 1850 |
85 |
|
600 × 500 × 1975 |
85 |
|
750 × 650 × 1975 |
125 |
|
800 × 765 × 1975 |
230 |
|
850 × 835 × 1975 |
253 |
|
— |
283 |
|
Outdoor model |
Dimensions (W × D × H, mm) |
Net weight (kg) |
|
DMC05WP1 |
787 × 352 × 829 |
40 |
|
DMC07WP1 |
787 × 352 × 829 |
40 |
|
DMC12WP1 |
787 × 352 × 1240 |
61 |
|
DMC17WT3 |
950 × 400 × 1245 |
85 |
|
DMC22MT1 |
1133 × 520 × 1323, vertical installation; 1305 × 1133 × 974, horizontal installation |
104 |
|
DMC27MT1 |
1293 × 520 × 1491, vertical installation; 1473 × 1293 × 974, horizontal installation |
120 |
|
Outdoor model |
Dimensions (W × D × H, mm) |
Net weight (kg) |
|
DML07WP1 |
1037 × 352 × 829 |
53 |
|
DML12WP1 |
1037 × 352 × 1240 |
95 |